Examples of possible ducting – Bosch DPH36652UC User Manual

Page 6

Advertising
background image

6

Typical installation
The height from the countertop to the bottom of
the hood is 24" to 30”.These hoods are not
recommended to be used over indoor grills.

1. Choose vent options

The hood is designed ready to be used for
vertical discharge as shown below.
Note: see also Fig. 1-3-5 for Cabinet
preparation.

If desired, the hood can be converted for
horizontal discharge as shown below.
Note: see also Fig. 2-3-5 for Cabinet and rear
wall preparation.

DUCTING
Provide a Round Duct having a diameter of 8”
see Figure 2 and Figure 3 for location on
cabinet bottom.

Install a 1/2” conduit from the service panel long
enough to reach the hood once it is installed.
Power supply must be rated for 120 V AC, 60
Hz. 15 or 20 A.

Examples of possible ducting

Round
Duct

Soffit

Transition

Filter

Blower

Lamp

Hood

24” to 30”

Horizontal discharge

Vertical discharge

Recirculating
* Optional accessory - Ductless
recirculation kit

Round
Duct

Soffit

Blower

Lamp

Filter

Transition

Hood

24” to 30”

24” to 30”

Hood

Lamp

Soffit

*Deflector

Blower

Filter

* Charcoal
filters

Advertising
This manual is related to the following products: