Causes for damages

9

CAUTION

Risk of damage due to corrosion. Always turn

appliance on when cooking to avoid condensation

buildup. Condensation can lead to corrosion

damages.

Always replace defective bulbs immediately to avoid an

overload of the remaining bulbs.

Risk of damage due to ingress of humidity into the

electronic circuitry. Never clean operator controls with a

wet cloth.
Surface damage due to incorrect cleaning. Clean

stainless steel surfaces in the grind direction only. Do not

use any stainless steel cleaners for operator controls.
Surface damage due to strong or abrasive cleaning

agents. Never use strong and abrasive cleaning agents.
Risk of damage from condensation back flow. Install

exhaust vent at a slight downward slope away from the

appliance (1° slope).

Protecting the environment

Unpack the appliance and dispose of the packaging in

line with environmental requirements.

General notes

Exhaust air mode

Note: Ventilation may not exit through an already

operational smoke or exhaust chimney, nor a duct used

for ventilating furnace installation areas.

If the ventilation is intended to pass through a smoke

or exhaust that is not in operation, the responsible

area heating inspector must give approval.

If the ventilation passes through an external wall, use a

telescope wall sleeve.

Ventilation line

Note: The manufacturer does not assume any warranty

for complaints attributable to the pipe section.

The device achieves its optimum performance by

means of a short, straight exhaust air pipe and as

large a pipe diameter as possible.

The optimum extraction performance is not achieved

and fan noise is increased if exhaust air pipes are long

and rough and if there is a large number of pipe bends

or diameters less than 5

15

/

16

” (150 mm).

The pipes or hoses for laying the exhaust air line must

consist of non-combustible material.

Round pipes
An inner diameter of 5

15

/

16

” (150 mm), but at least 4

3

/

4

(120 mm), is recommended.
Flat ducts
The inner cross-section must correspond to the diameter

of the round pipes.
Ø 5

15

/

16

” (150 mm) approx. 27 ½ sq in (177 cm

2

)

Ø 4

3

/

4

” (120 mm) approx. 17 ½ sq in (113 cm

2

)

Flat ducts should have no sharp deflections.

Use sealing strip for deviating pipe diameters.

Electrical connection

9

WARNING

RISK OF ELECTRIC SHOCK
Parts inside the appliance can have sharp edges.

The connection cable can be damaged. Do not

bend or pinch connection cables during installation.

Check your domestic installation before installing the

appliance. Pay attention to suitable fusing of your

domestic installation. The voltage and frequency of the