*TRG


Meaning and Type
Trigger Device Trigger

Description
This command generates a trigger when the trigger subsystem has BUS selected as its source. The command has the same
affect as the Group Execute Trigger (<GET>) command.

Command Syntax

*TRG

Parameters

(None)

Query Syntax

(None)

Related Commands

ABOR CURR:TRIG INIT TRIG[:IMM] VOLT:TRIG

<GET>

*TST?


Meaning and Type
Test Device Test

Description
This query causes the power supply to do a self-test and report any errors (see "Selftest Error Messages" in "Chapter 3 -
Turn-On Checkout" of the power supply Operating Guide).

Query Syntax

*TST?

Returned Parameters

<NR1>

0

Indicates power supply passed self-test.

Nonzero

Indicates an error code.

Related Commands

(None)