Insert installation, Masonry fireplace requirements, Zero-clearance (metal) fireplace requirements – Avalon Stoves 745 User Manual

Page 19: Drafting performance, Leveling bolt installation

Advertising
background image

Insert Installation

(for qualified installers only)

19

Travis Industries

93508133

4 020509

Masonry Fireplace Requirements

Chimney must have a clay tile liner or a stainless steel liner (positive connection)

Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert

Chimney height: 15' minimum; 33' maximum.

Entire fireplace, including chimney, must meet local building requirements

Zero-Clearance (Metal) Fireplace Requirements:

Must utilize a positive (full reline) or direct connection (block-off plate)

Must be manufactured by one of the following manufacturers:

• Marco • Majestic • Heatilator • Preway • Tempco • Superior

Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert

Entire fireplace, including chimney, must meet local building requirements

Chimney height: 15' minimum; 33' maximum. Minimum
cross section: 28.65 square inches

The damper ("

A

") and grate ("

B

") must be removed (see

the illustration to the right)

The smoke shelf ("

C

"), internal baffles ("

D

"), screen ("

E

"),

and metal or glass doors ("

F

") may be removed (if

applicable)

The masonry lining ("

G

"), insulation ("

H

"), and any

structured rigid frame members (metal sides, floor, door
frame, face of the fireplace, etc. – "

I

") may not be

removed or altered

C

B

F

I

D

E

A

G

H

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric
pressure, topography, or factors of the home (negative pressure from exhaust fans, chimneys, air
infiltration, etc.), may adversely affect draft. Travis Industries can not be responsible for external
forces leading to less than optimal performance.

Leveling Bolt Installation

Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth. To install,
raise the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the
insert. Adjust the bolts until they extend the same height as the hearth steps up. After the insert is
installed, fine-tune the leveling bolts to level the insert (see the illustration).

This distance is the

hearth step-up. The

leveling bolts should

stick out this far from the

base of the insert.

Fireplace

Hearth

The leveling bolts go

into the holes at the

rear corners of the

insert.

Advertising
This manual is related to the following products:

790