Installation test (exhaust check) – LG DLEX2450R User Manual

Page 27

Advertising
background image

ENGLISH

Check the duct condition

If the test displays four bars, check the exhaust system

for restrictions and damage. Repair or replace the

exhaust system as needed.

NOTE: When the dryer is first installed, this test should

be performed to alert you to any existing problems with

the exhaust duct in your home. However, since the

test performed during normal operation provides more

accurate information on the condition of the exhaust

duct than does the installation test, the number of bars

displayed during the two tests may not be the same.

INSTALLATION TEST (Exhaust check)

Restricted or Blocked Airflow

Avoid long runs or runs with multiple

elbows or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed

or restricted.

IMPORTANT: Do not interrupt the test cycle, as this

could result in the wrong results.

NOTE: Even if no bars are displayed during the test

cycle, some restrictions may still be present in the

exhaust system. Refer to the Venting the Dryer section

of this manual for complete exhaust system and venting

requirements.

Check the Error Code before you call for service

Error Code

Possible Causes

Solutions

tE1

or

tE2

Temperature sensor failure

Turn off the dryer and call for

service.

HS

Humidity Sensor failure.

Turn off the dryer and call for

service.

PS

or

PF

or

nP

Electric dryer power cord is not con-

nected correctly, or house power

supply is incorrect.

House fuse is blown, circuit breaker

has tripped, or power outage has oc-

curred.

Check the power supply or the

connection of power cord to

the terminal block. Refer to the

Connecting Electric Dryers

section of this manual for

complete instructions.

Reset circuit breaker or replace

fuse.

Do not increase the fuse capacity.

If the problem is a circuit over-

load, have it corrected by a

qualified electrician.

Excess or crushed

transition duct

Lint

buildup or

blockage

Crushed or

damaged exhaust

Too many elbows

or exhaust too long

27

MFL62512850_EN_110415.indd 27

4/15/11 9:11:43 AM