Wwarning, Connecting gas dryers, 1 connecting gas dryers – LG DLEX8377NM User Manual

Page 9

Advertising
background image

I N S TA L L AT I O N I N S T RU C T I O N S

I N S TA L L AT I O N I N S T RU C T I O N S

Electrical Requirements for Gas Models Only

Do not, under any circumstances, cut or

remove the third (ground) prong from the power

cord. Failure to follow this warning can result in

fire, explosion, or death.

For personal safety, this dryer must be properly

grounded. Failure to follow this warning can result

in fire, explosion, or death.

The power cord of this dryer is equipped with

a 3-prong (grounding) plug which mates with

a standard 3-prong (grounding) wall outlet

to minimize the possibility of electric shock

hazard from this appliance. Failure to follow this

warning can result in fire, explosion, or death.

This dryer must be plugged into a

120-VAC, 60-Hz. grounded outlet protected by

a 15-ampere fuse or circuit breaker. It is also

recommended that a separate circuit serving

only this dryer be provided. Failure to follow this

warning can result in fire, explosion, or death.

Where a standard 2-prong wall outlet is

encountered, it is your personal responsibility

and obligation to have it replaced with a

properly grounded 3-prong wall outlet. Failure

to follow this warning can result in fire, explosion,

or death.

Installation and service must be performed

by a qualified installer, service agency, or the

gas supplier. Failure to do so can result in fire,

explosion, or death.

Use only a new stainless steel flexible

connector and a new AGA-certified

connector. Failure to do so can result in fire,

explosion, or death.

A gas shutoff valve must be installed within

6 ft. (1.8 m) of the dryer. Failure to do so can

result in fire, explosion, or death.

The dryer is configured for Natural Gas when

shipped from the factory. Make sure that the

dryer is equipped with the correct burner

nozzle for the type of gas being used (Natural

Gas or Liquefied Petroleum). Failure to do so

can result in fire, explosion, or death.

If necessary, the correct nozzle (for the LP

nozzle kit order part number 4948EL4002B)

should be installed by a qualified technician

and the change should be noted on the dryer.

Failure to do so can result in fire, explosion,

or death.

All connections must be in accordance with

local codes and regulations. Failure to do so

can result in fire, explosion, or death.

Gas dryers MUST exhaust to the outdoors.

Failure to do so can result in fire, explosion,

or death.

3/8" NPT Gas

Connection

Gas Supply

Shutoff Valve

Connecting the Gas Supply

Make sure that the gas supply to the laundry

room is turned OFF. Confirm that the type

of gas available in your laundry room is

appropriate for the dryer. The dryer is

prepared for Natural Gas with a 3/8-in. NPT

gas connection.
Remove the shipping cap from the gas

connection at the back of the dryer. Be

careful not to damage the threads of the gas

connector when removing the shipping cap.
Connect the dryer to your laundry room’s gas

supply using a new flexible stainless steel

connector with a 3/8-in. NPT fitting.
Securely tighten all connections between the

dryer and your laundry room’s gas supply.

Turn on your laundry room’s gas supply and

check all pipe connections (both internal and

external) for gas leaks with a noncorrosive

leak-detection fluid.

1

2

3

4

High-Altitude Installations

The BTU rating of this dryer is AGA-certified for

elevations below 10,000 feet.

If your gas dryer is being installed at an elevation

above 10,000 feet, it must be derated by a

qualified technician or gas supplier.

Electrical Connection

Plug dryer into a

120-VAC, 60-Hz.

grounded 3-prong

outlet.

CONNECTING GAS DRYERS

(cont.)

1/8" NPT Pipe

Plug

AGA/CSA-Certified

Stainless Steel

Flexible Connector

w

WARNING:

To reduce the risk of fire, electric shock, or injury to persons when using this

appliance, follow basic precautions, including the following:

1

1

CONNECTING GAS DRYERS

Gas supply requirements:

As shipped from the factory, this dryer is

configured for use with natural gas. It can be

converted for use with LP (Liquefied Propane)

gas. Gas pressure must not exceed 13 in.

water column.

A qualified service or gas company technician

must connect the dryer to the gas service.

Failure to do so can result in fire, explosion,

or death.

Isolate the dryer from the gas supply system

by closing its individual manual shutoff valve

during any pressure testing of the gas supply.

Failure to do so can result in fire, explosion,

or death.

Supply line requirements:

Your laundry room must have a rigid gas

supply line to your dryer. In the United States,

an individual manual shutoff valve MUST be

installed within at least 6 ft. (1.8 m) of the dryer,

in accordance with the National Fuel Gas Code

ANSI Z223.1 or Canadian gas installation code

CSA B149.1. A 1/8-in. NPT pipe plug must

be installed. Failure to do so can result in fire,

explosion, or death.

If using a rigid pipe, the rigid pipe should be

1/2-in. IPS. If acceptable under local codes

and ordinances and when acceptable to your

gas supplier, 3/8-in. approved tubing may be

used where lengths are less than 20 ft. (6.1

m). Larger tubing should be used for lengths

in excess of 20 ft. (6.1 m). Failure to do so can

result in fire, explosion, or death.

Connect the dryer to the type of gas shown on

the nameplate. Failure to do so can result in fire,

explosion, or death.

To prevent contamination of the gas valve,

purge the gas supply of air and sediment

before connecting the gas supply to the dryer.

Before tightening the connection between the

gas supply and the dryer, purge remaining air

until the odor of gas is detected. Failure to do

so can result in fire, explosion, or death.

DO NOT use an open flame to inspect for gas

leaks. Use a noncorrosive leak-detection fluid.

Failure to do so can result in fire, explosion, or

death.

Use only a new AGA- or CSA-certified gas

supply line with flexible stainless steel

connectors. Failure to do so can result in fire,

explosion, or death.

Securely tighten all gas connections. Failure to

do so can result in fire, explosion, or death.

Use Teflon

®

tape or a pipe-joint compound that

is insoluble in Liquefied Petroleum (LP) gas on

all pipe threads. Failure to do so can result in fire,

explosion, or death.

DO NOT attempt any disassembly of the dryer;

any disassembly requires the attention and

tools of an authorized and qualified service

person or company. Failure to do so can result

in fire, explosion, or death.

w

WARNING:

To reduce the risk of fire, electric shock, or injury to persons when using this

appliance, follow basic precautions, including the following:

w

WARNING:

To reduce the risk of fire, electric shock, or injury to persons when using this

appliance, follow basic precautions, including the following:

Advertising
This manual is related to the following products: