Electrical connections warning, Warning – LG LCE3610SB User Manual

Page 24

Advertising
background image

24

I N S TA L L AT I O N I N S T RU C T I O N S

IMPORTANT SAFETY INSTRUCTIONS

• Be sure your cooktop is installed and grounded

properly by a qualified installer or service

technician.

• This cooktop must be electrically grounded in

accordance with local codes or, in their absence,

with the National Electrical Code ANSI/NFPA No.

70, latest edition in the United States.

PROVIDING THE ELECTRICAL CONNECTION

Install the junction box under the cabinet and run

120/240 or 120/208 volt, AC wire from the main

circuit panel.
NOTE: DO NOT connect the wire to the circuit

panel at this time.

ELECTRICAL REQUIREMENTS

Observe all governing codes and local

ordinances.

1

A 3-wire or 4-wire single-phase 120/240 or

120/208 volt, 60 Hz AC-only electrical supply is

required on a separate circuit fused on both

sides of the line (time-delay fuse or circuit

breaker is recommended). DO NOT fuse

neutral. The fuse size must not exceed the

circuit rating of the appliance specified on the

nameplate.

2

36″ Radiant cooktop can consume up to 9200W

at 240 VAC. A 50 Amp circuit breaker with wire

guage #8 AWG must be used.

30″ Radiant cooktop can consume up to 7700W

at 240 VAC. A 40 Amp circuit breaker with wire

guage #8 AWG must be used.

NOTE: Wire sizes and connections must

conform with the fuse size and rating of the

appliance in accordance with the National

Electrical Code ANSI/NFPA No. 70, latest

edition, and local codes and ordinances.

3

The appliance should be connected to the fused

disconnect (or circuit breaker) box through

flexible armored or nonmetallic sheathed cable.

The flexible armored cable extending from this

appliance should be connected directly to the

grounded junction box. The junction box should

be located as shown on page 21 or 23 with as

much slack as possible remaining in the cable

between the box and the appliance, so it can be

moved if servicing is ever necessary.

4

A suitable strain relief must be provided to

attach the flexible armored cable to the junction

box.

ELECTRICAL CONNECTIONS

WARNING

The electrical power to the cooktop must be

shut off while line connections are being

made. Failure to do so could result in serious

injury or death.

WARNING

An extension cord must not be used with this

appliance. Such use may result in a fire,

electrical shock, or other personal injury.

Advertising
This manual is related to the following products: