Closet ventilation requirements, English – LG DLE2350R User Manual

Page 11

Advertising
background image

ENGLISH

For cabinet installation with a door, minimum ventilation openings in the top of the cabinet

are required.

Recommended installation spacing for cabinet installation

30"

(76.1cm)

5"**

(12.7 cm)

1"**

(2.5 cm)

1"

(2.5 cm)

1"

(2.5 cm)

27"

(68.6 cm)

9"**

(22.9 cm)

7"* (17.8 cm)

7"* (17.8 cm)

The dimensions shown are for the recommended spacing.

Recommended installation spacing for recessed or closet

installation, with stacked washer and dryer

1"* (2.5 cm)

5 "**

(14 cm)

1/2

77

1/2

"

(196.8 cm)

*Required spacing

** For side or bottom

venting, 2 inches

(5.1 cm) spacing is

allowed.

*Required spacing

** For side or bottom venting, 2 inches

(5.1 cm) spacing is allowed.

Closet ventilation requirements

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in

the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm

2

) must be installed

no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in.

(155 cm

2

) must be installed no more than one foot above the floor. One example shown uses vent

grilles in the door.

INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACkING kIT

WARNING : If you are installing your dryer using an optional pedestal base or stacking kit, please

refer to

Optional Accessories in this manual or to the instructions for your pedestal or stacking kit

before proceeding with the installation.

11

MFL62512864_EN_110725.indd 11

2011.7.25 9:59:28 AM