INSTALLATION

Water Line Installation Instructions

Inst all the shutoff valve on the nearest
frequently used drinking water line.

1

SHUT OFF THE MAIN WATER SUPPLY
Turn on the nearest faucet to relieve the

pressure on the line.

2

C H O O S E T H E V A LV E L O C A T I O N

C h o o s e a l o c a t i o n
for the valve that is
easily accessible. It is
best to connect into
the side of a vertical
water pipe. When it is
necessary to connect
into a horizontal water pipe, make the
connection to the top or side, rather
than at the bottom, to avoid drawing off
any sediment from the water pipe.

3

D R I L L T H E H O L E F O R T H E VA LV E
Drill a 1/4 in. (6.35 mm) hole in

the water pipe using

a sharp bit. Remove

any burrs resulting

f r o m d r i l l i n g t h e

h o l e i n t h e p i p e .

Be careful not to

allow water to drain into the drill. Failure to

drill a ¼ in. hole may result in reduced ice

production or smaller cubes.

4

FASTEN THE SHUTOFF VALVE
Fasten the shutoff valve to the cold water

pipe with the pipe clamp.

5

TIGHTEN THE PIPE CLAMP
Tighten the clamp screws until the sealing

washer begins to swell.

NOTE: Do not overtighten clamp or

you may crush the tubing.

6

ROUTE THE TUBING
Route the tubing between the cold water

line and the refrigerator.

Route the tubing through a hole drilled in

the wall or floor (behind the refrigerator or

adjacent base cabinet) as close to the wall

as possible.

NOTE

The hookup line cannot be white, plastic
tubing. Licensed plumbers must use only
copper tubing (NDA tubing #49595 or #49599)
or Cross Link Polyethylene (PEX) tubing.

WARNING

When using any electrical device (such
as a power drill) during installation, be
sure the device is battery powered,
double insulated or grounded in a
manner that will prevent the hazard of
electric shock.

Pipe Clamp

Saddle-Type

Shutoff Valve

Vertical Cold

Water Pipe

NOTE

Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed
plumber

by norms and regulations of your

country.

Pipe Clamp

Clamp Screw

Washer

Inlet End

NOTE

Be sure there is sufficient extra tubing (about
8 feet [2.4 m] coiled into 3 turns of about
10 in. [254 mm] diameter) to allow the
refrigerator to move out from the wall after

installation.