How to Install the Unit

All supporting parts should be secured to firm wood,
masonry, or metal.
This unit is designed for installation in standard double hung
windows with actual opening widths from 22" to 36".
The top and bottom window sash must open sufficiently to
allow a clear vertical opening of 1

4" from the bottom of the

upper sash to the window stool.

NOTICE

About

1

/

2

"

30"~60"

Awning

Cooled air

Fence

Over 20"

Heat

radiation

14

36

22

12

Shipping
Screws

(Keep the screws for later use.)

Remove 4 screws which fasten the cabinet at both

sides and at the back.

Preparation Of Chassis

1. To prevent vibration and noise, make sure the unit

is installed securely and firmly

2. Install the unit where the sunlight does not shine

directly on the unit.

3. The outside of the cabinet must extend outward for

at least 11" and there should be no obstacles, such
as a fence or wall, within 20" from the back of the
cabinet because it will prevent heat radiation of the
condenser.
Restriction of outside air will greatly reduce the
cooling efficiency of the air conditioner.

All side louvers of the cabinet must remain exposed to the outside of the structure.

4. Install the unit slightly tilted so the back is slightly lower than the front (about

1

/

2

").

This will force condensed water to flow to the outside.

5. Install the unit with the bottom between 30"~60" above the floor level.