INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT

IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, please

refer to

Optional Accessories in this manual or to the instructions for your pedestal or stacking kit

before proceeding with the installation.

CLOSET VENTILATION REQUIREMENTS

Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup

in the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 sq. cm) must be

installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24

sq. in. (155 sq. cm) must be installed no higher than 1 feet above the floor. One example shown uses

vent grilles in the door.

The dimensions shown are for the recommended spacing.

Recommended installation spacing for recessed or closet

installation, with stacked washer and dryer

For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet

are required.

Recommended installation spacing for cabinet installation

7"* (17.8 cm)

9"*

(22.9 cm)

7"* (17.8 cm)

5"**

(12.7 cm)

27"

(68.6 cm)

1"*

(2.5 cm)

(2.5 cm)

(2.5 cm)

32 "

(82.65 cm)

9/16

48 in.

2

*

(310 cm

2

)

3"* (7.6 cm)

3"* (7.6 cm)

1"* (2.5 cm)

24 in.

2

*

(155 cm

2

)

6"* (15.2 cm)

76"

(193 cm)

27"

(68.6 cm)

1"

(2.5 cm)

1"

(2.5 cm)

5 "**

(14 cm)

1/2

*Required spacing

** For side or bottom

venting, 2 inches

(5.1 cm) spacing is

allowed.

*Required spacing

** For side or bottom venting, 2 inches

(5.1 cm) spacing is allowed.