Installation location requirements
W
WARNING
3FBEBMMJOTUBMMBUJPOJOTUSVDUJPOTDPNQMFUFMZCFGPSFJOTUBMMJOHBOEPQFSBUJOHZPVSESZFSIt is important that you review this entire
manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust
requirements are provided on the following pages.
%POPUPQFSBUFZPVSESZFSBUUFNQFSBUVSFCFMPX¡' ¡$
BOEUFNQFSBUVSFPWFS¡' ¡$
"UMPXFSUFNQFSBUVSFT
UIFESZFSNJHIUOPU
shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages,
closets, mobile homes or sleeping quarters. Contact your local building inspector.
t"MFWFMGMPPSXJUIBNBYJNVNTMPQFPGJODI DN VOEFSFOUJSFESZFS$MPUIFTNBZOPUUVNCMFQSPQFSMZ BOEBVUPNBUJDTFOTPSDZDMFT
may not operate correctly if dryer is not level.
t'PSBHBSBHFJOTUBMMBUJPO ZPVXJMMOFFEUPQMBDFUIFESZFSBUMFBTUJODIFT DN BCPWFUIFGMPPS*GVTJOHBQFEFTUBM ZPVXJMMOFFE
JODIFT DN UPUIFCPUUPNPGUIFESZFS
Clearances
INSTALLATION SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
5IFGPMMPXJOHTQBDJOHEJNFOTJPOTBSFSFDPNNFOEFEGPSUIJTESZFS5IJTESZFSIBTCFFOUFTUFEGPSTQBDJOHPGJODIFT DN
DMFBSBODFPO
the sides and rear. Recommended spacing should be considered for the following reasons:
There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one to the
other. Too much vibration, it could cause them to make noise or touch each other causing paint damage and making even more noise.
t"MPDBUJPOUIBUBMMPXTGPSQSPQFSFYIBVTUJOTUBMMBUJPO"HBTESZFS
must be exhausted to the outdoors. See
7FOUJOHUIFESZFS.
t"HSPVOEFEFMFDUSJDBMPVUMFUMPDBUFEXJUIJOGU DN PGFJUIFS
side of the dryer. See
$POOFDUJOHFMFDUSJDESZFST.
t"TUVSEZGMPPSUPTVQQPSUUIFUPUBMESZFSXFJHIUPGMCT
kg). The combined weight of a companion appliance should also
be considered.
tNo other fuel-burning appliance can be installed in the same
closet as a dryer.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEGPSFBTFPGJOTUBMMBUJPO
and servicing.
t"EEJUJPOBMDMFBSBODFTNJHIUCFSFRVJSFEGPSXBMM EPPSBOEGMPPS
moldings.
t"EEJUJPOBMTQBDJOHTIPVMECFDPOTJEFSFEPOBMMTJEFTPGUIFESZFS
to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
t$PNQBOJPOBQQMJBODFTQBDJOHTIPVMEBMTPCFDPOTJEFSFE
24 in.
2*
(155 cm
2
)
18" min.*
(45.7 cm)
1"*
(2.5 cm)
30"
(76.1 cm)
30"
(76.1 cm)
5"**
(12.7 cm)
48 in.
2*
(310 cm
2
)
14" max.*
(35.6 cm)
3"
*
(7.6 cm)
3"
*
(7.6 cm)
1"
(2.5 cm)
27"
(68.6cm)
1"
(2.5 cm)
1"*
(2.5 cm)
5"**
(12.7 cm)
14" max.*
(35.6 cm)
18" min.*
(45.7 cm)
0"
(0 cm)
39"
(99.1 cm)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
NOTE
NOTE