Controlling the multiple product, Rs-232c, Transmission / receiving protocol – LG M3700C-BA User Manual
Page 55
Advertising
A13
Controlling the Multiple Product
RS-232C
21. Tiling Mode(Command : d d)
Change a Tiling Mode.
Transmission
[d][d][][Set ID][][Data][x]
* The data can not be set to 0X or X0 except 00.
Acknowledgement
[d][][00][][OK/NG][Data][x]
22. Tile H Position(Command : d e)
To set the horizontal position .
Transmission
[d][e][][Set ID][][Data][x]
* The data range is from 00 to 64(in Hex).
Acknowledgement
[e][][Set ID][][OK/NG][Data][x]
Transmission / Receiving Protocol
Data
Description
00
Tiling mode is off.
12
1 x 2 mode(column x row)
13
1 x 3 mode
14
1 x 4 mode
...
...
44
4 x 4 mode
▲
▲