Connecting dry closures, Setting axlink and prolink address numbers, Lighting application drawings – AMX Control Card RDC-PDC User Manual

Page 2

Advertising
background image

2

RDC-PDC Control Card, Dual or Three Phase

Connecting Dry Closures

Use the 8 (+ common) dry closures with a WPD8 eight-button wall panel.

Each contact closure connection (1 - 8) is pre-programmed with a default
preset. The table below shows the default presets for each contact clo-
sure.

Setting AXlink and PROlink Address Numbers:

Lighting Application Drawings


FIG. 5 Dry closures connection

Dry Closure Default Presets

Contact Closure

Default Function

1

Channel 1 at 100% in 1 second

2

Channel 2 at 100% in 1 second

3

Channel 3 at 100% in 1 second

4

Channel 4 at 100% in 1 second

1

2

3

4

5

6

7

8 COM

Each contact (1 - 8) is pre-
programmed with a default preset.

Refer to the AMX Lighting Control
System
instruction manual for
details on dry closure default presets
and recording new presets.

Dry Closure Default Presets (Cont.)

5

Channel 5 at 100% in 1 second

6

Channel 6 at 100% in 1 second

7

Pack on (channels 1-6)

8

Pack off (channels 1-6

All other channels are undefined.

FIG. 6 Setting AXlink and PROlink address numbers.

AXlink Address

PROlink Address

Test

Set the AXlink address number
(1-255) for the RDC-DC. This
number must match the device
number in your Axcess program.

Use the PROlink DIP switch to set
the PROlink address number for the
RDC-DC (1-10).

Pin 8 on the PROlink DIP switch is
a test switch that turns all circuits on
to full.

FIG. 7 Method A

Method A
RDC-PDC/120, 3 Phase
6 dimmers, 0 switches