American Standard Colony Oval 1742 Series User Manual

Installation instructions, Whirlpool/bathing pool 1742 series, Colony oval

Advertising
background image

INSTALLATION INSTRUCTIONS

753571-100

© American Standard Inc. 2004
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

COLONY OVAL™

WHIRLPOOL/BATHING POOL

1742 SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.

After inspection and during installation, protect the bath from construction damage. AFTER INSTALLATION, AND
BEFORE ENCLOSING WITH WALLBOARD, TILE, ETC., WATER TEST THE UNIT AND CHECK FOR LEAKS.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout

1803 mm

(71)

ROUGH
FLOOR

1-1/2 O.D.

TAILPIECE

OUTLINE OF

CUTOUT-USE
TEMPLATE

292 mm
(11-1/2)

1041 mm

(41)

555mm

(21-7/8)

82mm

(3-1/4)

51mm

(2)

535mm

(21)

98mm

(3-7/8)

C

L OF DRAIN

OUTLET

605mm

(23-7/8 )

1-1/2 N.P.T.M.

THREADS

35mm

(1-3/8)

305mm(12) X 229 mm(9)
CUTOUT IN FLOOR FOR DRAIN

98mm
(3-7/8)

PROVIDE ACCESS

TO PUMP FOR

SERVICING ON ALL

INSTALLATIONS

ON/OFF

SWITCH

PUMP MAY
EXTEND
TO THE RIM

SEE FTTG.SPECS

FOR DIMENSION

CL OF SUPPLIES

C/L OF
SPOUT

C/L OF

VALVES

C/L OF

SHOWER ARM

1651-1981mm

(65-78)

OPTIONAL

102mm
(4)

305mm

(12)

(2) AIR VALVES

BATH

SUPPORT

MATERIAL

GENERAL SPECIFICATIONS FOR 1742 WHIRLPOOL

71 x 41 x 23-7/8 In.(1805 x 1040 x 606mm)

119 Lbs. (54 Kg.)

680 Lbs. (308 Kg.)

67 Gal. (254 L)
50 Gal. (190 L)

49 x 26 In. (1245 x 660mm)
62 x 34 In. (1588 x 864mm)

16-7/8 In. (429mm)

32 Lbs./Sq.Ft. (157 Kgs./Sq.m)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.1 HP, 9.9 AMPS, 120V.

PUMP

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)

IMPORTANT: Water test unit before installation
and enclosure!

Advertising