Press MODE to place the controller in one of the following modes.

Press the

button to select the fan operating mode.

In automatic mode, the fan runs only when heating or cooling is
activated.

In continuous mode, the fan runs continuously and the sym-
bol is displayed. NOTE: If the “smart fan” feature is enabled,
the fan will run only when heating or cooling will be activated
during unoccupied mode.

Depending on how the controller has been configured (see page 4,
item 9), it displays either the measured indoor humidity level or the
measured outdoor temperature.

The actual (measured) temperature is normally displayed. To view
the temperature setpoint, press one of the

buttons once. The

setpoint is displayed for 5 seconds and is indicated by the sym-
bol.

To modify the temperature setpoint, press one of the

buttons

until the desired temperature is displayed.
NOTE: If the controller is in automatic heat/cool changeover, the
setpoint is automatically reduced or raised by 1°C (2°F) when the
controller switches to heating mode or to cooling mode respectively.
For example, if you place the setpoint at 24°C (75°F) while in heat-
ing mode, the setpoint will become 25°C (77°F) in cooling mode and
will return to 24°C (75°F) when the controller switches back to heat-
ing mode.

The humidity adjustment can be placed in manual mode or in auto-
matic mode (see page 4, item 11).

Manual Adjustment

In manual mode, the user sets the humidity level (5% to 60%).

Automatic Adjustment

In automatic mode, the controller sets the humidity level based on
the outdoor temperature to prevent ice formation or condensation
on windows. However, the user can apply an offset (-9% to 9%). For
example, the user can enter a negative offset if there is too much
condensation on the windows.

Procedure

The procedure to set the humidity level (in manual mode) or the off-
set (in automatic mode) is as follows:

1)

Press the Mode button for 3 seconds.
One of the following displays appears:

System fault

Temperature adjustment

Fan operating
mode selection

System operating
mode selection

System
operating mode

Fan is in continuous mode

Unoccupied
mode is On

Outdoor
temperature or
indoor humidity

Indoor temperature

Auxiliary heat is On

Heating is On

Cooling is On

Emergency heat
mode

Dual-energy
mode

Humidifier
is On

Appears when the
temperature setpoint
is displayed

5. Operation

5.1

System Operating Mode (Heating/Cooling)

HEAT

The system is in heating mode.

COOL

The system is in cooling mode.

AUTO

The system is in automatic changeover. (The system
switches between heating mode and cooling mode to main-
tain the desired temperature.)

OFF

Both heating or cooling are off.

EHEAT

The system is in emergency heat mode. Only auxiliary heat-
ing is used when there is a call for heat.

5.2

Fan Operating Mode (On/Auto)

5.3

Indoor Humidity / Outdoor Temperature Display

Outdoor

temperature

Indoor
humidity

5.4

Temperature Adjustment

5.5

Humidity Adjustment