Allied Telesis AT A35/SX AT-A35-SX/SC User Manual

Page 2

Advertising
background image

USA Headquarters

|

19800 North Creek Parkway

|

Suite 200

|

Bothell

|

WA 98011

|

USA

|

T: +1 800 424 4284

|

F: +1 425 481 3895

European Headquarters

|

Via Motta 24

|

6830 Chiasso

|

Switzerland

|

T: +41 91 69769.00

|

F: +41 91 69769.11

Asia-Pacific Headquarters

|

11 Tai Seng Link

|

Singapore

|

534182

|

T: +65 6383 3832

|

F: +65 6383 3830

www.alliedtelesis.com

© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

617-00458-00 Rev. G

Rapier Series Uplink Modules

| Gigabit & Fast Ethernet

Model

Port

Connector

Cable Type

1

Max Cable Length

AT-A35/SX

1000SX

SC

50/125 micron
multimode fiber
62.5/125 micron
multimode fiber

550 m (1,804ft)

2

275 m (902ft)

3

AT-A35/LX

1000LX

SC

9/125 micron
singlemode fiber

50/125 or 62.5/125
micron multimode fiber

3km (1.8mi) increasing to
10km (6mi) if linking
two 1000LX models
550m (1804ft)

2

AT-A39/T

10/100/1000T

4

RJ-45

CAT5
CAT5E

100 to 150m (328 to 492ft)
200m (656ft)

AT-A40/SC

100FX
(multimode fiber, 1300nM)

SC

50/125 or 62.5/125
micron multimode fiber

2km

AT-A40/MT

100FX
(multimode fiber, 1300nM)

MT-RJ

50/125 or 62.5/125
micron multimode fiber

2km

AT-A41/SC

100FX
(multimode fiber, 1300nM)

SC

50/125 or 62.5/125
micron multimode fiber

2km

AT-A41/MT

N100FX
(singlemode fiber, 1300nM)

MT-RJ

9/125 micron
singlemode fiber

15km

AT-A42/GBIC 1000X

Varies per GBIC Refer to GBIC documentation Refer to GBIC documentation

(ATR)
Model

singlemode/
multimode

Wavelength Tx power (dBm)

Sensitivity (dBm)

Saturation (dBm)

AT-A35/SX

multimode fiber

850

-4 to -9.5

-12.5 @ 62.5uM,
-13.5 @ 50uM

0

AT-A35/LX

singlemode fiber
multimode fiber
multimode fiber

1310

-3 to -9.5@9uM,
-3 to [email protected],
-3 to -11.5@50uM

-20

-3

AT-A40/SC

multimode fiber

1310

-14 to [email protected],
-14 to -22.5@50uM

-34.5

-14

AT-A40/MT

multimode fiber

1310

-14 to [email protected],
-14 to -22.5@50uM

-34.5

-14

AT-A41/SC

singlemode fiber

1310

-14 to -20

-31

-8

AT-A41/MT

singlemode fiber

1310

-14 to -20

-31

-8

Competitive Matrix

Ordering Information

AT-A35/SX

1 x 1000SX/SC uplink with SC connector

AT-A35/LX

1 x 1000LX/SC uplink with SC connector

AT-A39/T

1 x 1000T uplink with RJ-45 connector

AT-A40/SC

100FX multimode fiber uplink
with SC connector

AT-A40/MT

100FX multimode fiber uplink
with MT connector

AT-A41/SC

100FX singlemode fiber uplink
with SC connector

AT-A41/MT

100FX singlemode fiber uplink
with MT connector

AT-A42/GBIC

Uplink module with 1 GBIC bay
(Uses Allied Telesis standards-based
GBIC modules. GBIC ordered separately)

1. Refer to the IEEE 802.3 standards for further cable information.
2. Assumes a fiber optic cable rating of 500 Mhz/Km.

(Maximum cable length is 500m at a cable rating of 400 Mhz/Km.)

3. Assumes a fiber optic cable rating of 200 Mhz/Km.

(Maximum cable length is 220m at a cable rating of160 Mhz/Km.)

4. Early versions of the AT-A39/T operate at 1000Mbps only.

10/100/1000Mbps operation is available only if the AT-A39/T
Uplink Module is installed in a Rapier G6, Rapier G6F or
Rapier i model, otherwise operation is fixed at 1000Mbps.

Advertising