Operation, Special features – Amcor AD 400E User Manual

Page 5

Advertising
background image

Operation

5

4

1. Automatic Dehumidification

After setting the desired humidity, the unit will maintain the desired humidity automatically.

2. Continuous Drainage

In order to remove excessive moisture from the air, with a minimum amount of attention,
the humidifier is equipped with a pump to continually discharge condensed water.
The continuous drainage point is high at the back of the unit, making it easy to reach and
convenient to attach the supplied drainage tube. Water can be collected in a large container,
or pumped to the outside.

3. Air Filter

The dehumidifier features a cartridge type washable air filter. To access it press the top
of the front grill. Once cleaned, again press the front grill back into position to lock the
filter in place.

IMPORTANT

The operational temperature range for this unit is 41°F to 95ºF.
This dehumidifier should not be used at temperatures below 41°F.
Running the unit above the temperature of 95ºF will cause the compressor
to stop as its over heat protector becomes activated.

Operation Instruction

1. POWER KEY

Press to turn unit “ON” or “OFF”.

2. FAN SPEED

Press to select fan speed “HI” or “LOW”.

3. TIMER

a. Press the “TIMER” key to set the time desired (1-24 hour).
b. Once the set time has come to an end, the unit will turn off automatically.
c. Pressing the “POWER” key before the set time has been reached,

the set time will be canceled when the unit turns off.

4. HUMIDITY SETTING

Press to select the Humidity desired (RH 80% / 70 % / 60 % / 50 % / or CONTINOUS).
When the room humidity is less than the selected humidity, the unit will turn off automatically.
The unit will turn on automatically when the room humidity is higher than the selected humidity.
Actual Humidity and Indicated Humidity may vary by 5% (+ or -).

5. ALARM INDICATOR

If this indicator illuminates, it means the water pump can not drain the water from the tank.
Check to see that the drain hose is not blocked or bent, restricting the water flow.

6. DEFROST

Periodically the defrost light will come on to indicate that the ice that forms as part of the process
at low room temperatures is being melted off the cold internal coil. It should go off once the
coil is sufficiently frost free to continue effective dehumidification.

Control Panel

Special Features