Connectionname, Hba_ww_id, Hostmode – HP ProLiant DL380 Server User Manual

Page 46: Acu scripting error messages, Connectionname hba_ww_id hostmode

Advertising
background image

ConnectionName

This option is a user-defined string used as the connection name for the specified HBA.

The string can consist of the following:

A maximum of 16 characters

Embedded space characters but cannot end with a space character

Any of the following characters: a–z, A–Z, 0–9, !, @, #, *, (, ), -, _, +, :, ., /, and [space]

HBA_WW_ID

This option specifies which HBA, based on its assigned WWN, is modified by the configuration
changes.

HostMode

This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage
array for the selected operating system. The available host modes for an HBA are device-specific.
Not all modes are available on all devices. Not all HBAs support a HostMode.

The following operating system options might be available:

Default

Microsoft Windows

OpenVMS

Tru64

Linux

Solaris

Netware

HP-UX

ACU scripting error messages

Comment or clarification

Error message

Error code

The ACU process cannot be initiated. You might see this error
message if you are not authenticated to use ACU or if ACU
is already running.

General error.

1

ACU cannot save one or more controller configurations.

Error saving controller.

268

Controller is locked by another machine or
user.

278-282

Error communicating with controller.

290

An error occurred during the configuration process, but ACU
cannot identify the error because there is an internal ACU
error.

Internal error.

516

This error message occurs if you attempt to add an odd
number of drives to an array that has RAID 1 logical drives,
and the controller does not support RAID-level migration.

Array requires an odd number of drives.

1052

This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than

Cannot remove physical drives from
existing array.

1053

already exist in the array. ACU interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so ACU prevents the
script from running.

46

Toolkit utilities

Advertising