Selecting devices, Viewing firmware details, Selecting devices viewing firmware details – HP Smart Update Manager User Manual

Page 27

Advertising
background image

4.

Check each component that you want to update on the selected target. If there is a dependency
failure, click Failed Dependency to see potential solutions for the component.

NOTE:

HP Integrity servers only: If you see an error that reads, "Mismatch Found" or

"Mismatch Found Update Required", click the message to view the Select Devices screen. For
more information on this error, see

“Viewing firmware mismatch details (HP Integrity servers

only)” (page 28)

.

5.

Click OK.

Selecting devices

On the Select Devices screen, select the devices on the target that you want to update. You can
also review any dependency problems that need to be resolved before HP SUM begins the update
installation.

NOTE:

HP Integrity servers only: Some targets that are part of a domain allow you to update the

entire domain at the same time. If you do not want to update the entire domain at once, select the
check box next to the partitions you want to update.

To select devices:
1.

To reach the Select Devices screen, click Select Devices on the Select Bundles or Select
Components screen.

2.

Select the check box for the device that you want to update. The Status field displays messages
about the selected device. If you cannot update a device, the Status field displays a brief
explanation.

NOTE:

HP Integrity servers only: If a multi-blade server displays a Mismatch Firmware

or Mismatch Firmware Update Required error, HP SUM resolves the mismatch as part
of the update when you click Install. For more information on a firmware mismatch, see

“Viewing firmware mismatch details (HP Integrity servers only)” (page 28)

.

3.

View any errors or warnings displayed at the bottom of the screen. Correct errors before
continuing. HP SUM cannot proceed with updates until you resolve the errors. Warnings do
not prevent the installation, but continuing an installation without correcting the problem that
caused the warning might cause more serious problems. To continue without resolving the
warnings, select Ignore Warnings.

4.

After you have selected the devices, click OK to exit this screen.

Viewing firmware details

You can view the firmware detail screen from these screens:

Review/Install Updates

Select Bundles

Select Components

To open the view firmware details, do one of the following:

Click Installed Version on the Select Bundles or Select Components screen.

HP Integrity servers only: Click Mismatch Found on the Review/Install Updates screen, if
displayed.

The View Firmware Details screen provides information about:

Reviewing and installing updates

27