"Refresh Data" link on the far right corner of the screen above the table that lists workloads
discovered by Systems Insight Manager.
HP SIM identification of a VM host and its virtual machines inconsistent
If you open the Capacity Advisor "Edit Scenario" screen and see this message:

Error generating screen.
Attempting to create second instance of
(Scenario_systemLayout_nameHeader_system_name_popupContent*)

this means that the HP SIM identification of a VM host is inconsistent with the identification of the
virtual machines associated with it. Suggested action: Re-identify the VM host and its virtual machines
to correct this issue. See the HP Systems Insight Manager Help to learn how to identify or discover
systems from the top menu bar or from the command line. You need to be a privileged administrator
user or root to do this action.
You may then want to click the "Refresh Data" link on the Matrix OE visualization Workload tab
to ensure the information is also up-to-date for Capacity Advisor. If this problem persists, you may
need to run vseassist on the VM host to determine why Systems Insight Manager is not correctly
identifying the VM host and its constituents.
Data for node appears to differ from one profile viewer to another
Though a profile viewer looks the same and behaves similarly from whichever location it is accessed,
the data displayed for a node may indeed differ – it may be actual historic data or an aggregation
of data, depending on the location from which the viewer is accessed or the type of system being
viewed. For a discussion of data handling in a profile viewer, see

“Using the Profile Viewer”

(page 67)

.

Miscellaneous user interface issues

Menu fly-out forces scrolling in Microsoft Internet Explorer browser
This occurs with some IE browser security settings. When you mouse over the menu picks, the menu
looks compressed, showing one entry and a scrolling mechanism for the other menu choices.
Systems Insight Manager checks for this setting on entry and shows this message to help you correct
the situation:

Your browser's zone security settings are not compatible with the HP SIM popup menu.
The following setting must be enabled in your current zone:
Internet Options | Security | Custom Level | Miscellaneous | Allow script-initiated windows without size or
position constraints
(This setting is enabled by default for the "medium-low" security level, such as the "local intranet" zone.)