background image

Installing the controller hardware 12

4.

For each SCSI bus, manually set the SCSI ID on each drive to a unique value in the range of 0 to
15, except 7 (which is reserved for controller use). For detailed instructions, consult the
documentation that is provided with the drive.

5.

Attach a multi-device SCSI cable from the internal connector of the controller to the non-hot-
pluggable hard drives. (The cable might have been provided with the server.)

6.

Replace the access panel, and secure it with the thumbscrews if any are present.

CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating

the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.

Connecting external storage

1.

On the rear of the server, connect the external cable to the VHDCI connector on the controller, and
tighten the lock screws on the cable connector.

2.

Attach the other end of the cable to the storage enclosure, and tighten the lock screws on the cable
connector.

SCSI cable part numbers

NOTE: If you require additional cables, order them by the option kit number.

SCSI cable type

Cable length

Option kit number

Cable assembly number

External VHDCI cable

1.8 m (6 ft)

3.7 m (12 ft)

7.3 m (24 ft)

11.9 m (39 ft)

341174-B21

341175-B21

164604-B21

150214-B21

313374-001

313374-002

313374-004

313374-005

Internal multi-device cable

varies

166389-B21

148785-001