Hardware options installation, Introduction, Hp product quickspecs – HP ProLiant ML110 G7 Server User Manual

Page 30: Sas and sata drive options, Drive installation guidelines, Installing a drive

Advertising
background image

Hardware options installation 30

Hardware options installation

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and
identify similar steps to streamline the installation process.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

CAUTION:

To prevent damage to electrical components, properly ground the server before

beginning any installation procedure. Improper grounding can cause electrostatic discharge.

HP product QuickSpecs

For more information about product features, specifications, options, configurations, and compatibility, see
the product QuickSpecs on the HP Product Bulletin website (

http://www.hp.com/go/productbulletin

).

SAS and SATA drive options

The server provides non-hot-plug capability through an embedded SATA controller. To obtain hot-plug

capability, install an optional controller and hot-plug cable option kit. The server supports up to four
non-hot-plug or hot-plug LFF drives and up to eight hot-plug SFF drives.

Drive installation guidelines

When adding drives to the server, observe the following general guidelines:

The system automatically sets all drive numbers.

If only one drive is used, install it in the bay with the lowest drive number.

When drives are grouped together into the same drive array, they must be of the same capacity to
provide the greatest storage space efficiency.

Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options are:

The embedded controller supports non-hot-plug SATA drives. Drive LEDs are not supported.

Optional SATA controllers support hot-plug SATA drives and drive LEDs.

Optional SAS controllers support hot-plug SAS or SATA drives and drive LEDs.

Installing a drive

CAUTION:

To prevent improper cooling and thermal damage, do not operate the server unless

all bays are populated with either a component or a blank.

Advertising