Brocade events, Brocade switch events, 73 brocade switch events – HP Storage Essentials NAS Manager Software User Manual

Page 494

Advertising
background image

Event Management

462

7.

Change the value assigned to the cimom.ClariionEventPollInterval property. The

value is in milliseconds. In the example below, the polling interval is set to 5 minutes.

cimom.ClariionEventPollInterval=300000

8.

When you are done, click Save.

9.

Restart the service for the management server for your changes to take effect.
While AppStorManager is restarting, users are not able to access the management server. The

AppStorManager service must be running for the management server to monitor elements.

Important

: While the AppStorManager service is stopped, the following occurs:

Users are not be able to access the management server.

The management server is unable to monitor elements at this time.

Brocade Events

This section describes the following:

Brocade Switch Events

” on page 462

Supported Brocade Events

” on page 463

Brocade Switch Events

When a Brocade switch generates an event, it assigns a code to the event instead of an event

severity level. So, the software assigns an event severity level to the event according to the event's

code. This lets you filter Brocade switch events by severity level in Event Manager, as described in

the following table.

NOTE:

Events regarding firmware downloads are removed from the following table since the

management server cannot be made aware of those events.

Table 73

Brocade Switch Events

*Code

Event

Severity

Level

*Name

Description

0

Minor

EV_OBJ_CHANGED

A physical fabric object (switch

port or fabric) has changed

state.

1

Major

EV_OBJ_DELETE

One or more physical fabric

objects (device port, switch, or

fabric) have disappeared.

Advertising