HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 27

Advertising
background image

Troubleshooting 27

Error code

Details

VCSU_ERROR_PRIMARY_BACKUP_HEALTH_NOT_OK

The health of primary or standby module is not

OK. The update cannot proceed.

VCSU_ERROR_MIN_TARGET_VERSION_ROLLBACK_
DOWNGRADE

The target version does not support the

downgrade of Virtual Connect firmware without
deletion of domain configuration.

VCSU_ERROR_MIN_VCM_VERSION_ROLLBACK_

DOWNGRADE

The current version of Virtual Connect firmware

does not support the downgrade without

deletion of domain configuration.

VCSU_ERROR_PRIMARY_NOT_IN_LOWER_BAY_FOR_

DOWNGRADE

Presence of subordinate module on lower bay

before primary module will not allow

downgrade.

VCSU_ERROR_ROLLBACK_DOWNGRADE_WILL_NOT_
PROCEED_FOR_MANUAL_ENET_ACTIVATION

Rollback downgrade will not proceed for
manual activation of E-net modules.

VCSU_ERROR_VCM_LOCKED_BY_VCEM_AND_FW_

MAINTENANCE_MODE

VC is locked by VCEM Firmware Maintenance

mode. Downgrade will not proceed.

VCSU_ERROR_ROLLBACK_DOWNGRADE_WILL_NOT_
PROCEED_FOR_SERVERPOWERON_NOSAFE

Powered ON servers or server profile migration
since upgrade and performing downgrade may

result in duplicate MAC/WWN in the domain.

Power OFF the servers to avoid the

MAC/WWN duplication and perform the
downgrade.

VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_
LOWEST_BAY

Failed to activate lowest E-net bay for rollback

VCSU_ERROR_ROLLBACK_FAILED_TO_ACTIVATE_ODDSIDE
_MODULE

Failed to activate odd side modules for rollback

VCSU_ERROR_ROLLBACK_ACTIVATE_FAILURE

Rollback activation failed

VCSU_ERROR_ROLLBACK_ODDMODULE_MANAGED_
STATUS_NOT_NORMAL

Odd module managed status is not Normal.

VCSU_ERROR_ADD_USER_FAILED

Unable to add user

VCSU_ERROR_REMOVE_USER_FAILED

Unable to remove user

VCSU_ERROR_SET_NAME_FAILED

Unable to set the user name

VCSU_ERROR_AND_EXIT_FROM_UPDATE

Fatal error. One or more modules is preventing

VCSU from continuing. Correct conditions listed
above and retry.

VCSU_ERROR_MODULE_FAILOVER_FAILED

Module did not come up with proper role after

failover.

VCSU_ERROR_FIRMWARE_EXTRACT_FAILED

Failed to extract the VC firmware package

VCSU_ERROR_GET_ENCLOSURE_INFORMATION_FAILED

Failed to get enclosure information

VCSU_ERROR_SET_TO_SLAVE_FAILED

Failed to set the module to subordinate state

VCSU_ERROR_SET_TO_AUTO_FAILED

Failed to set the module to auto state

VCSU_ERROR_VC_LOGIN_FAILED

Failed to log in to Virtual Connect

VCSU_ERROR_ADD_VCM_USER_FAILED

Failed to add VC user in Onboard

Administrator

VCSU_ERROR_PRIMARYMODULE_BEING_IN_EVENBAY_
AND_NO_BACKUP_MODULE

Rollback will not proceed since primary module
is in even bay and there is no backup module.

VCSU_ERROR_RESOLVE_HOST_INFO_FAILED

Failed to resolve the hostname

VCSU_ERROR_VCM_SKIP_FAILOVER

Virtual Connect does not have a valid Backup

module. Cannot failover.

Advertising