Figure 2 data integrity check components, Data integrity check and raid manager, 2 data integrity check components – HP StorageWorks XP Remote Web Console Software User Manual

Page 10

Advertising
background image

Overview of Data Integrity Check

10

Figure 2

shows the Data Integrity Check components and their functions for Oracle data check. For

requirements (such as product name or versions), refer to

Data Integrity Check Operating

Environments and Prerequisites

” on page 11.

Figure 2

Data Integrity Check components

Data Integrity Check and RAID Manager

Data Integrity Check is configured and operated using Data Integrity Check commands in RAID
Manager XP. For RAID Manager operations, refer to the

HP StorageWorks RAID Manager XP User’s

Guide.

You must specify the volume to be checked, and the type of check using RAID Manager (the types
are different depending on versions). The files (constructed in RAW volume) that are checked are:
Data, Redo log and Control. If data is written from the host server to the array, the data check is
initiated by channel adapters (CHIPs) that support Data Integrity Check.

NOTE:

The check is not started when the data is read.

When invalid data is detected, the error is reported from the CHIPs to RAID Manager, and a log
(syslog) is generated from RAID Manager.

Advertising
This manual is related to the following products: