Operations, Power up the server, Power down the server – HP ProLiant DL560 Gen8 Server User Manual

Page 18: Extend the server from the rack

Advertising
background image

Operations 18

Operations

Power up the server

To power up the server, press the Power On/Standby button.

Power down the server

Before powering down the server for any upgrade or maintenance procedures, perform a backup of critical
server data and programs.

IMPORTANT:

When the server is in standby mode, auxiliary power is still being provided to the

system.

To power down the server, use one of the following methods:

Press and release the Power On/Standby button.
This method initiates a controlled shutdown of applications and the OS before the server enters standby
mode.

Press and hold the Power On/Standby button for more than 4 seconds to force the server to enter

standby mode.
This method forces the server to enter standby mode without properly exiting applications and the OS.
If an application stops responding, you can use this method to force a shutdown.

Use a virtual power button selection through iLO.
This method initiates a controlled remote shutdown of applications and the OS before the server enters
standby mode.

Before proceeding, verify the server is in standby mode by observing that the system power LED is amber.

Extend the server from the rack

WARNING:

To reduce the risk of personal injury or equipment damage, be sure that the rack is

adequately stabilized before extending a component from the rack.

1.

Pull down the quick release levers on each side of the server.