Installing lights-out management features, Error messages, Configuring array controllers – HP ProLiant DL360 G4p Server User Manual

Page 15

Advertising
background image

Post-installation tasks 15

Installing Lights-Out management features

If a RILOE board was purchased for the server or the server was purchased with an iLO controller
installed, use the following procedure to complete the installation. Do not attempt to install the device

driver until after the operating system installation is complete.

IMPORTANT:

The Microsoft® Hardware Wizard detects the RILOE board as a PCI Memory

Controller and the iLO controller as a Base System Device. The Hardware Wizard continues to

appear until the driver installation has been completed.

1.

Click Next at the Found New Hardware Wizard window.

2.

Select Search for a Suitable Driver for My Device.

3.

Click Next.

4.

Select Specify a Location, and clear the Floppy Drive and CD-ROM options.

5.

Click Next.

6.

Enter the following path in the textbox:

C:\HPDRVRS

7.

Click OK.

8.

Click Next at the Driver Files Search Results screen, and then click Finish.

Error messages

After the RILOE driver is installed, the following errors can occur:

In the Device Manager screen, two entries appear for the ATI Video Controller. One of these entries
has a yellow exclamation mark indicating that no driver is installed.

In the Event Viewer, the following message appears:

Unable to map address range for graphics card

These errors result from RILOE and the server using the same video controller. The operation of the server

is not affected by these error messages.
To disable one entry for the ATI Video Controller and prevent the error messages from occurring:

1.

Right-click the Device Manager entry for the ATI Video Controller that has a yellow exclamation

mark.

2.

Select Disable.

After the ATI Video Controller entry is disabled or when the server is rebooted, a red X appears in place

of the yellow exclamation mark. The red X indicates that the device is disabled. The disabled entry does

not affect the operation of the server.

Configuring array controllers

If an array controller has been purchased with the server, run the online ACU to set up the remaining

physical drives for use.

Advertising