HP Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem User Manual

Page 146

Advertising
background image

Configuring the Virtual Connect domain using the CLI 146

6

Start with modules in Bays

3–6, create a profile (add

4 connections), hotplug
modules into Bays 7 and

8, then edit the profile.

Port

Connected to

1

Bay 3

2

Bay 4

3

Bay 5

4

Bay 6

5

Bay 3

6

Bay 4

7

Bay 5

8

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6
Bay 7 Bay 8

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the
profile.

This profile is not useful

after the hotplug. To

resolve this issue, delete
connections 5–8, save

the profile, and then

scenario 5 applies.

7

Start with modules in Bays

5 and 6, create a profile,

hotplug modules into Bays
3 and 4, then edit the

profile.

Port

Connected to

1

Bay 5

2

Bay 6

Bay 3 Bay 4

Bay 5 Bay 6

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the

profile.

8

Start with modules in Bays

5–8, create a profile,

hotplug modules into Bays
3 and 4, then edit the

profile.

Port

Connected to

1

Bay 5

2

Bay 6

4

Bay 7

5

Bay 8

Bay 3 Bay 4

Bay 5 Bay 6
Bay 7 Bay 8

Add connection is

disallowed because the

current FC module
configurations do not

match the existing

connections in the
profile.

9

Start with FCoE-capable

modules in Bays 1 and 2,

then create a profile and
add connections.

Port

Connected to

1

Bay 1

2

Bay 2

Bay 1 Bay 2

Port

Connected to

1

Bay 1

2

Bay 2

3

Bay 1

4

Bay 2

5

Bay 1

6

Bay 2

7

Bay 1

8

Bay 2

Add connection, 6 times

Advertising