AMX NetLinx Integrated Controller NI-3100 User Manual

Page 7

Advertising
background image

Introduction

3

NI-2100, NI-3100, NI-4100 Hardware Reference Guide

NI-2100 Specifications

Dimensions (HWD):

• 3.47" x 17.00" x 3.47" (8.81 cm x 43.18 cm x 8.82 cm)
• 2 rack units high

Power Requirement:

700 mA @ 12 VDC

Memory:

• 64 MB SDRAM
• 1 MB Non-volatile (NV) SRAM

Compact Flash:

128 MB or more - Upgradeable (see Other AMX Equipment)
Note: AMX may increase Flash size at any time in response to
market availability (refer to product’s online catalog page for current Compact
Flash size provided).

Weight:

4.50 lbs (2.04 kg)

Enclosure:

Metal with black matte finish

Certifications:

FCC Part 15 Class B, CE, and IEC 60950

Front Panel LEDs:
• LINK/ACT:

Green LED blinks when the Ethernet cables are connected and
terminated correctly. Also blinks when receiving Ethernet data
packets.

• Status:

Green LED blinks to indicate that the system is programmed and communi-
cating properly.

• Output:

Red LED blinks when the Controller transmits data, sets channels On and
Off, sends data strings, etc.

• Input:

Yellow LED blinks when the Controller receives data from button pushes,
strings, commands, channel levels, etc.

• RS-232/422/485:

3 sets of red and yellow LEDs light to indicate that DB9 Ports 1 - 3 are trans-
mitting or receiving RS-232, 422, or 485 data.

• Relay:

4 red LEDs light to indicate the relay channels 1 - 4 are active (closed).
These LEDs reflect the state of the relay on Port 4.

• IR/Serial:

4 red LEDs light to indicate the IR/Serial channels 1 - 4 are
transmitting control data on Ports 5 - 8. LED indictor for each IR port remains
lit for the length of time that IR/Serial data is being generated.

• I/O:

4 yellow LEDs light when the I/O channels 1 - 4 are active. The LED for each
I/O port reflects the state of that particular port.

Rear Panel Components:
• RS-232/422/485 (Ports 1 - 3): 3 RS-232/422/485 control ports using DB9 (male) connectors with XON/

XOFF (transmit on/transmit off), CTS/RTS (clear to send/ready to send), and
300-115,200 baud.

• ICSNet:

2 RJ-45 connectors for ICSNet interface (provided by optional
ICSNet daughter card).

• ICSHub Out:

RJ-45 connector provides data to a Hub connected to the Controller (pro-
vided by optional ICSNet daughter card).

• Relay (Port 4):

• Four-channel single-pole single-throw relay ports
• Each relay is independently controlled.
• Supports up to 4 independent external relay devices
• Channel range = 1-4
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
8-pin 3.5 mm mini-Phoenix (female) connector provides relay termination

• Digital I/O (Port 9):

4-channel binary I/O port for contact closure with each input being capable of
voltage sensing. Input format is software selectable with interactive power
sensing for IR ports.

Advertising
This manual is related to the following products: