Figure 78 detailed media display dialog box, 78 detailed media display dialog box, Table 29 – HP H-series Enterprise Fabric Management Suite Software User Manual

Page 130

Advertising
background image

130 Managing Ports

Figure 78

Detailed Media Display dialog box

Table 29

Port Information data window—Digital Diagnostics Monitoring

Field

Description

Details

Ports with media that support DDM show the information button (i). Click (i) to

view the measured values and the associated vendor-defined status in the

Detailed Media Display dialog box (

Figure 78

). The status values are Normal,

LowAlarm, LowWarning, HighWarning, and HighAlarm.

LowWarning and HighWarning values indicate the normal range of

operation.

Falling below the LowWarning or exceeding the HighWarning should not

cause link failure.

Falling below the LowAlarm or exceeding the HighAlarm may cause link

failure.

Temperature (C)

Temperature for the media in the port measured in degrees Celsius

Voltage (V)

Supply voltage for the media in the port measured in Volts

Tx Bias (mA)

Transmitter laser bias current for the media in the port measured in milliamps

Tx Power (mW)

Transmitter output power for the media in the port measured in milliwatts

Rx Power (mW)

Receiver optical power for the media in the port measured in milliwatts