Is the power supply’s ac power good led off, Is the drive enclosure back panel ok led off – HP 2000I G2-Modular-Smart-Array User Manual

Page 50

Advertising
background image

50

Troubleshooting

Is a connected port’s Expansion Port Status LED off?

Is a connected port’s Network port link status LED off?

Is the power supply’s AC Power Good LED off?

Is the drive enclosure back panel OK LED off?

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The link is down.

Check cable connections and reseat if necessary.

Inspect cable for damage.

Swap cables to determine if fault is caused by a

defective cable. Replace cable if necessary.

In SMU, review event logs for indicators of a specific

fault in a host data path component.

Contact an authorized service provider for assistance.

See

Isolating a controller module expansion port

connection fault

on page 54.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The link is down.

Use standard networking troubleshooting procedures to

isolate faults on the network.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply is not

receiving adequate power.

Verify that the power cord is properly connected and

check the power source it is connected to.

Check that the power supply FRU is firmly locked into

position.

Check the event log for specific information regarding

the fault.

Isolate the fault.

Contact an authorized service provider for assistance.

Answer

Possible Reasons

Actions

No

System functioning properly.

No action required.

Yes

The power supply unit or a fan

is operating at an

unacceptable voltage/RPM

level, or has failed.

When isolating faults in the power supply, remember that

the fans in both modules receive power through a

common bus on the midplane, so if a power supply unit

fails, the fans continue to operate normally.

Check that the power supply FRU is firmly locked into

position.

Check that the AC cord is connected to a power

source.

Check that the AC cord is connected to the power

supply.

Advertising