Resetvcm, Supportdump – HP Virtual Connect FlexFabric 10Gb24-port Module for c-Class BladeSystem User Manual
Page 14
Commands 14
Display all modules in an enclosure:
vcsu -a report -i 192.168.1.100 -u Administrator -p password -l VCpackage
resetvcm
Log into the specified interconnect bay and restart the Virtual Connect Manager service. This is the same
process as the menu option "Reset VC Manager" from the Virtual Connect user interface.
Item
Description
Syntax
vcsu -a resetvcm -i <IP> -u <USER> -p <PWD>
Parameters:
IP
IPv4 address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length
is 1 character. Maximum length is 40 characters.**
PWD
Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.
Example
Reset the modules in an enclosure:
vcsu -a resetvcm -i 192.168.0.100 -u Administrator -p password
supportdump
Log into VC Manager using the supplied credentials and access Virtual Connect to request a support
information (debug dump) download. VCSU saves that file in the current directory as the file name supplied
by Virtual Connect. A functioning VC Manager domain is required for this action.
Item
Description
Syntax
vcsu -a supportdump -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -vcp <VCM
PASS> -l <LOCATION>
Parameters:
IP
IPv4 address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length
is 1 character. Maximum length is 40 characters.**
PWD
Password of the OA user. Minimum length is 3 characters. Maximum length is 40
characters.**
VCM USER
Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 1 character. Maximum length is 31 characters.
VCM PASS
Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31
characters.
LOCATION
Full path, including file name, to save the support dump file. If not provided, VCSU saves the
support dump file to the file name that VCM provides and downloads it to the current directory.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across
local and all remote enclosures in the Virtual Connect domain.
Example