Checking servernet lan subsystem status, Interpreting the cpus display, Example – HP NonStop G-Series User Manual

Page 394

Advertising
background image

Monitoring Hardware Components

Guardian User’s Guide 425266-001

19 -16

Checking ServerNet LAN Subsystem Status

Interpreting the CPUS Display

The format of the CPUS detailed information display is:

The numbered elements in this display are:

System contains the numbers and names of the systems known to be connected to

the network.

0<--CPU States-->15 contains symbols indicating the status of each processor in a

system:

OS Version contains the version of the operating system running on each system.

For additional information about SCF and its commands, see the SCF Reference Manual
for G-Series Releases
.

Example

To check the configuration characteristics, status, and operating-system version of all
processors connected to the system \C2, enter:

2-> CPUS \C2

A report such as this is displayed on your home terminal:

See

Interpreting the CPUS Display

on page 19-16 for an explanation of the elements in

this display.

Checking ServerNet LAN Subsystem Status

The ServerNet LAN Systems Access (SLSA) subsystem supports parallel local-area
network (LAN) I/O, allowing S-series servers to communicate across a ServerNet
System Area Network (SAN) and access Ethernet devices through various LAN
protocols. The SLSA subsystem contains the following SCF objects:

Processes

Monitors

System 0<--CPU States-->15 OS Version
116 \C2 1111,....,....,.... P40

Symbol

Meaning

1

Processor is active

0

Processor is inactive

Period (.)

Nonexistent processor

NOT CONNECTED

A known system is not currently connected to the network

System 0<--CPU States-->15 OS Version
116 \C2 1111,....,....,.... P40

1

2

3

1

2

3