Upgrading procedure – HP Fusion ioFX 410GB PCIe Accelerator User Manual

Page 17

Advertising
background image

Software installation 17

NOTE:

When using PCI pass-through, if you upgrade the firmware on an IO Accelerator, you

must cycle the power for the change to take place. Restarting the virtual machine does not apply

the change.

Upgrading device firmware from VSL 1.x.x or 2.x.x to 3.x.x

CAUTION:

You cannot downgrade an HP IO Accelerator device firmware to an earlier version

after you have upgraded the device.

CAUTION:

Upgrading IO Accelerator devices that were previously configured for VSL 1.x.x or

2.x.x to work with VSL 3.x.x requires a low-level media format of the device. No user data is
maintained during the media format process. Be sure to backup all data on your IO Accelerator

device as instructed before upgrading the firmware.

Version 3.1.x of the HP IO Accelerator VSL supports new features, including the latest generation of IO

Accelerator architecture and improved Flashback protection. These features require the latest version of the

firmware. Every IO Accelerator device in a system running 3.1.x or later must be upgraded to the latest

version of the firmware.
For example, if you have a system running 2.3.1 HP IO Accelerator VSL with IO Accelerator devices

previously installed, and you want to install new IO Accelerator Gen2 devices (that require the latest version

of the firmware), then you will need to upgrade all of the existing devices to the latest firmware version.
Upgrade path
Depending on the current version of your HP IO Accelerator device, to preserve the internal structure of the

device, you might have to perform multiple upgrades. The following path is the minimum upgrade path that

you must follow. Upgrade the HP IO Accelerator VSL software on the system, and upgrade the firmware to

the compatible version in the following order:
1.2.4 > 1.2.7 > 2.1.0 > 2.2.3 > 3.1.x
For VSL upgrade information for the HP IO Accelerator, see the HP IO Accelerator Release Notes on the HP

website (

http://www8.hp.com/us/en/support-drivers.html

). General upgrade instructions, including the

firmware update instructions, are available in the HP IO Accelerator User Guide for each operating system.
Overformatting not supported
The –o overformat option is not supported in the 3.x.x VSL software. All upgraded HP IO Accelerator

devices are formatted to the maximum advertised capacity, regardless of whether the device was

overformatted prior to the upgrade.

Upgrading procedure

Be sure to follow the upgrade path and make sure that all previously installed IO Accelerator devices are

updated with the appropriate 2.3.1-compatible firmware.
If you plan to use IO Accelerator Gen1 devices and IO Accelerator Gen2 devices in the same host, perform

this upgrade on all existing IO Accelerator Gen1 devices before installing the new IO Accelerator Gen2

devices.

1.

Prepare each existing IO Accelerator device for upgrade:

a.

Backup user data on each IO Accelerator device.

Advertising