HP ProLiant DL180 Server User Manual
Page 61
Using LO100 61
o
DOS: ipmitool 20 c0 29 01 00 00 02 00 08
o
Linux: ipmitool raw 0x30 0x29 0x01 0x00 0x00 0x02 0x00 0x08
•
To set telnet outbound to 0x03:
o
CLP: oemhp I 20 c0 20 18 00 29 01 00 00 02 01 03 b8
o
DOS: ipmitool 20 c0 29 01 00 00 02 01 03
o
Linux: ipmitool raw 0x30 0x29 0x01 0x00 0x00 0x02 0x01 0x03
•
To set SSH inbound to 0x08:
o
CLP: oemhp I 20 c0 20 18 00 29 01 00 01 02 00 08 b3
o
DOS: ipmitool 20 c0 29 01 00 01 02 00 08
o
Linux: ipmitool raw 0x30 0x29 0x01 0x00 0x01 0x02 0x00 0x08
•
To set SSH outbound to 0x03:
o
CLP: oemhp I 20 c0 20 18 00 29 01 00 01 02 01 03 b7
o
DOS: ipmitool 20 c0 29 01 00 01 02 01 03
o
Linux: ipmitool raw 0x30 0x29 0x01 0x00 0x01 0x02 0x01 0x03
For example, to restore the default setting using telnet in Windows®:
1.
Log in to the CLP interface from a Windows® Telnet client.
2.
Change the directory to map1 using the command:
cd map1
3.
Set input default to 0x08 using the command:
oemhp I 20 c0 20 18 00 29 01 00 00 02 00 08 b4
4.
Set output default to 0x03 using the command:
oemhp I 20 c0 20 18 00 29 01 00 00 02 01 03 b8
5.
Log out.