Term setting dialog box, Expiration lock function), The term setting dialog box – HP XP20000XP24000 Disk Array User Manual

Page 21: Prohibiting changes to read/write even when the, Figure 4

Advertising
background image

4.

Select a CU from the tree.

The volume list displays a list of volumes in the specified CU. The volume list displays the

Retention Term column.

5.

Select and right-click the desired volume, and select Retention Term from the pop-up menu to

open the Term Setting dialog box (

Figure 4

on page 21).

6.

In the Term Setting dialog box, specify the retention term.

To extend the retention term indefinitely, select Unlimited.

Note:

If you select Unlimited, you will need to ask your HP service representative to change the

retention term when you want to change it.

7.

Select OK to close the Term Setting dialog box.

The settings that you have made are displayed in blue and italics.

Note:

The settings have not been applied to the storage system.

8.

To apply the settings, click Apply in the Data Retention window.

A message appears and asks if you want to apply the settings to the storage system.

9.

Click OK.

The settings are applied to the storage system.

Term Setting Dialog Box

The Term Setting dialog box (

Figure 4

on page 21) enables you to specify a retention term, which is the

period during which attempts to change the access attribute to Read/Write are prohibited.

Figure 4 The Term Setting Dialog Box

The Term Setting dialog box displays the following items:

Term: The following boxes enable you to specify a retention term.
• The

years box enables you to specify the number of years within the range of 0 to 60. Note

that Data Retention Utility counts one year as 365 days, whether or not the year is a leap year.

• The

days box enables you to specify the number of days within the range of 0 to 21900.

For example, if 10 years 5 days or 0 years 3655 days is specified, the access attribute of the

volume cannot be changed to Read/Write during the next 3,655 days.

Unlimited: This button extends the retention term indefinitely.

OK: This button closes the Term Setting dialog box and applies the settings in the Term Setting

dialog box to the Data Retention window. Note that this button does not apply the settings to

the storage system. To apply the settings to the storage system, you must click Apply in the

Data Retention window.

Cancel: This button discards the settings in the Term Setting dialog box and closes the Term

Setting dialog box.

Prohibiting Changes to Read/Write Even When the Retention

Term is Over (Enabling/Disabling the Expiration Lock Function)

If you follow the procedure below, none of the Read Only volumes and Protect volumes can be changed

to Read/Write volumes, even after the retention term ends.
To prohibit attempts to change the access attribute to Read/Write even when the retention term is over:

XP24000 Data Retention Utility User's Guide