Installing the 5257 Tape Drive

5257/5257ACL Installation and User's Guide for NonStop Himalaya S-Series Tape Enclosures 522344-001

3 -3

Connecting the SCSI Cables to the Server

4. Repeat Steps 2 and 3 as applicable.

Connecting the SCSI Cables to the Server

Connect the free end of the SCSI cable at the server.

You can attach a 5257/5257ACL tape drive to a NonStop

Himalaya

S-series server using

one of the following, depending on your type of server:

ServerNet/DA

IOMF 2 CRU

PMF CRU

Supported connections for the 5257/5257 ACL tape drives are listed in

Table 3-2

.

Powering on the Tape Drive

1. Attach the male end of the power cord to a power outlet.

2. Press the power switch on the tape drive.

3. Verify that the tape drive powers on.

Power-On Self-Test

When power is applied, the tape drive performs a POST (Power-On Self-Test). The
POST finalizes in under ten seconds. While it is running, the tape drive responds BUSY
to SCSI commands and also responds to various SCSI messages.

If the Himalaya server tries to negotiate synchronous or wide transfers, the tape system
negotiates to asynchronous or narrow. Media may require more time than the duration of
POST to become ready.

WARNING.

For SCSI cables, be sure that the power to the tape drive is off before

connecting to the server.

Table 3-2. Connections Supported for 5257/5257ACL Tape Drives

Server

ServerNet / DA

IOMF CRU

IOMF 2 CRU

PMF CRU

S7000

YES

NO

NO

NO

S7400

YES

NO

YES

NO

S70000

YES

NO

YES

NO

S72000

YES

NO

YES

NO

S74000

YES

NO

YES

YES