Troubleshooting common problems, Table 3: troubleshooting installation (continued) – HP StorageWorks Ultra Density Optical Storage User Manual

Page 24

Advertising
background image

Troubleshooting

24

HP StorageWorks 30ux Standalone UDO Drive User’s Guide

Troubleshooting common problems

If the procedures in

Table 3

do not address or resolve your problem, visit

http://www.hp.com/go/udo

for additional assistance, or contact HP technical

support (see

Getting help

” on page 8).

Table 3: Troubleshooting installation

Problem

Solution

Drive will not power on

Check that the power indicator light

on the control panel is on. If it is not,

make sure the power switch on the

back panel is on.

Replace the power cord.

Host computer system does not

recognize the drive

Ensure the drive is connected and

powered on. The drive must be on

when booting the host computer for

the drive to be recognized.

If the drive is the last device on the

SCSI bus, check that it has been

terminated and that the maximum

cable length has not been

exceeded.

Check SCSI ID assignments and

resolve any conflicts.

Ensure you are connected to the

correct SCSI bus type. UDO drives

are LVDS devices.

If using a narrow (8-bit) HBA, make

sure that all addresses are in the

range 0 through 7.

For Windows operating systems, use

the device manager to rediscover

the drive.

For HP-UX, use

ioscan

to verify

that the HBA and attached devices

are claimed.

For other operating systems, refer to

the system administrators guide for

diagnosing missing peripherals.