Chapter Five - SCSI Bridge Electronics

Tandem 5142-xSE Rackmount Tape Subsystems User Guide

2 2

When the desired tape density appears, push the mode switch to select it. The selected setting is used
until the unit is repowered or reset. The choices offered are as follows:

C0

= Compressed format

40

= Non-compressed format

FF

= Density controlled by the host software

Note:

The setting from the last change of tape density is used as the default start-up value. Density may be
changed on a tape-by-tape basis any time the tape is at BOT during normal Performance Display
operation.

5.9

Setup Display Format

Configuration of the electronics is accomplished by using the mode switch. All values are retained in
nonvolatile memory. There are three setup menus: Setup 1 and Setup 2 contain configuration items
while Setup 3 is comprised of diagnostic and special utilities. Enter the setup menus by holding in the
mode switch while powering up the subsystem. The menu display system consists of the following
hierarchy:

Mode

Switch

*Set-Up*
Release

Button
to Start

Enter

Set-Up 1
PRESS to
Select

Enter
Set-Up 2
PRESS to
Select

Enter
Set-Up 3
PRESS to
Select

Exit
Set-Up
PRESS to
Select

Figure 25

Subsystem's setup menus

5.10

Setup Overview

Within each menu, the individual items generally take the following format on the four-line LCD:

SCSI ID:
[00]
PRESS to
Alter

Parameter

Setting

Instruction

LCD Setup Format

Figure 26

Subsystem's LCD setup format

•PARAMETER

denotes the configuration being reviewed or edited.

•SETTING

(in

SETUP 1

and

SETUP 2

) is the value that you can change.

•INSTRUCTION

describes what action should be taken if the mode switch is pressed. If the mode

switch is inactive for four seconds, the display changes. In general, the menu system is designed to show
continuously the current settings with the instruction

PRESS to Alter

, which allows the operator

the opportunity to alter the value.