Navigating menus – HP Console Management Controller User Manual

Page 78

Advertising
background image

4-28 Compaq Console Management Controller User Guide

Compaq Confidential – Need to Know Required

Writer: Hilary Stead Project: Compaq Console Management Controller User Guide Comments:

Part Number: 218258-002 File Name: e-ch4 Software.doc Last Saved On: 6/20/01 8:25 PM

4. Set up the properties for your terminal connection:

a. Enter a name for your connection in the New Connection dialog

box. Select an icon to represent the connection, then click OK. The
Phone Number dialog box displays.

b. In the Connect Using field, select Direct Connection to the COM

port to which the CMC is connected, then click OK. The Properties
dialog box displays.

c. Enter the following port settings, then click OK.

Bits per second (baud rate)

9600

Data bits

8

Parity

None

Stop bits

1

Flow control

None

5. The main menu of the CMC displays on the HyperTerminal interface.

Navigating Menus

CAUTION: All configuration changes made in a terminal program are retained in
CMC memory. If you change the Read and Write Community strings in the
terminal program setup independently from the Compaq Intelligent Rack
Manager Lite software, the software can no longer control the CMC.

Use Table 4-3 as a reference when navigating the CMC menus.

To change values in HyperTerminal, type the new value in the field and
press Enter.

To select and toggle values, press the spacebar.

To save changes and jump back to the previous menu, press Esc.

Advertising