Warning, Warning !!!! dealer & service center use only, Figure 2 – Aquacal HP7 User Manual

Page 20

Advertising
background image

Warning !

WARNING !!!! Dealer & Service Center Use Only

MAKE CERTAIN POWER SUPPLY TO HEATPUMP and CONTROLLER IS DISCONNECTED
PRIOR TO CONTINIUING. FAILURE TO DISCONNECT ELECTRICAL POWER MAY
RESULT IN SERIOUS INJURY OR DEATH.



1. String 18/2 cable from the controller to the heat pump.
2. Locate

the

MICROPROCESSOR POWER BOARD inside the heat pumps electric box. (See figure 1)

3. Connect the 18/2 cable from the controllers low voltage heater terminals to the MICROPROCESSOR

POWER BOARD Jandy terminal block, terminals Y and Z. (See figure 2)

4. RECONNECT POWER TO THE HEATPUMP.
5. Turn the POOL thermostat to the OFF position by pressing and holding the DOWN arrow key on the

control panel. Then press the POOL/SPA key once to select the SPA thermostat. Turn the SPA
thermostat to the OFF position by pressing and holding the DOWN arrow key on the control panel.

6. Simultaneously, press and hold, both the UP and Down arrow keys until CF1 is displayed.
7. While

CF1 is displayed press the POOL/SPA key repeatedly until LOC is displayed. Now press the UP

arrow repeatedly until 050 is displayed.

8. Press

the

POOL/SPA key repeatedly until JAO is displayed. Press the UP arrow repeatedly until 2 is

displayed.

9. After a delay of approximately 10 seconds, the water temperature is displayed. The controller’s

thermostats are now ready to control the heat pump.

Figure 2

Interface #2 Compatible Controllers-Water Temperature Controlled by Heater

Jandy

Compool

AquaSwitch

CP30

CP100T





The above controllers simply select the heat pump’s POOL or SPA thermostats. Listed below are
the steps to be followed for Interface #2.

20

Advertising