Section 1: General Information

2. Push the mode switch when Setup 1 appears. Screens cycle at a 2-second interval.

Enter
Set-Up 1

PRESS to
Select

SCSI ID:
[00]

PRESS to
Alter

Tape ID:
[00]

*NOT sel

ectable*

Tape
Term: On

*NOT sel

ectable*

Density:
[C0]

PRESS to
Alter

Rwr% 0.5
Ecc: 0.5

PRESS to
Alter

Exit

Set-Up 1

PRESS to
Select

Figure 13

Setup 1 configuration menu

3. Select the SCSI ID screen by pressing the mode switch when the SCSI ID screen

appears. This configuration menu item allows you to set the SCSI ID.

SCSI ID:
[00]
PRESS to
Alter

SCSI ID:

[01]
PRESS if
Done

SCSI ID:
[01]
PRESS to
Incremnt

Figure 14

Setting the SCSI ID


4. When the screen reads PRESS to Alter, press the mode switch.

5. The LCD shows the instruction PRESS to Increment. On the second line of the

display, a highlight indicates what digit is alterable. To increment the digit, press the
mode switch.

6. If no mode switch activity occurs for four seconds, the display shows PRESS if Done

to confirm the setting. The displays returns to the Setup 1 configuration menu. Press

the mode switch to exit the setup menus.

7. Check the new SCSI ID:

8. After setting the SCSI ID, cycle power to the drive using the AC power switch on the

rear of the tape drive. Once complete, check the stored SCSI ID is correct. The ID is
shown in the revision display on the main front panel LCD after power-up (ID is

shown in the three right most positions on the last line of the display). Alternately,
repeat the procedure in Checking and Setting the SCSI ID on page 13.

3.2.4

Starting and Testing the Tape Drives

This subsection describes the SCF commands to be used to start and test tape devices.

3.2.4.1 Starting a Tape Device

HP StorageWorks DAT 72 (Models 5242 and 5242-ACL) User's Guide

14 HP Part Number 528296-03 July 2005