Gfci circuit requirements: for model numbers – American Standard 2773L User Manual

Page 11

Advertising
background image

753737-100 Rev. C

11

All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.

WARNING: When using electrical products, basic precautions should always be observed, including the following:

1.

DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.

.

Grounding is required. The unit should be installed by a licensed electrician and grounded.

3.

Permit access for servicing motor as noted.

.

All building materials and wiring should be routed away from the pump body and heater (if equipped).

WHIRLPOOL ELECTRICAL INSTALLATION INSTRUCTIONS

ELECTRICAL DIAGRAM

READ AND FOLLOW ALL INSTRUCTIONS

B

L

A

C

K

W

H

IT

E

120 VAC

GND.

PUMP/MOTOR

WIRE SELECTION GUIDE

Maximum distance from

fusebox to motor

The sizes shown on this

chart are recommendations

for copper conductors

only. Always follow

local and national

electrical codes

Motor

Hi Performance

Rating

2.1 H.P.,

1.4 H.P.,

and 1.25 H.P.

50'

100'

115V Power Line

150'

200'

12

10

8

8

!

The whirlpool should be installed on a 120 vac,

15

amp dedicated

GFCI circuit.


The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.

Optional heater requires a separate 15 amp maximum GFCI circuit.

The whirlpool should be installed on a 120 vac,

20

amp dedicated

GFCI circuit.

The circuit should be hard-wired from the electrical power supply panel. The
circuit must be a three (3) wire circuit from the electrical supply panel. A
grounded neutral wire and a third wire, earth ground, are essential.

Optional heater requires a separate 15 amp maximum GFCI circuit.

GFCI CIRCUIT REQUIREMENTS:

FOR MODEL NUMBERS:

2422, 2425, 2645,

2771, 2805, 2908

ALL MODELS

7236, 2774

MODELS ENDING IN SUFFIX

LA, LAC, VA, VAC

6060, 2775, 2773, 2711, 2901

ALL MODELS

7236, 2774

MODELS ENDING IN SUFFIX

L, LC, V, VC

PLEASE SEE THE FOLLOWING TABLE FOR GFCI CIRCUIT REQUIREMENTS: