SL500 (M852x) Tape Library Installation and User’s Guide541531-010

5 -1

5

Configuring the M8520 Tape

Library for the NonStop S-Series
Server

The section covers:

Supported Connections

You can attach the M8520 tape library (control path and data path) to a NonStop

S-series server using one of the following:

!

ServerNet/DA

!

IOMF CRU

!

PMF CRU

Adding the Control Path and the Data Path

ServerNet/DA

To add the control path to the server configuration database, use the SCF ADD SCSI

command. Use the SCF ADD TAPE command to add the data path. Before issuing

these commands, check that the tape drive(s) and tape library are installed properly.
To add the control path:

-> SCF

-> ADD SCSI $M8520, SENDTO STORAGE, PRIMARYLOCATION
(1,1,51), PRIMARYSAC 1, SCSIID 5, PRIMARYCPU 0, BACKUPCPU 1

-> START SCSI $M8520

-> STATUS SCSI $M8520, DETAIL

Supported Connections

5-1

Adding the Control Path and the Data Path

5-1

Note.

The control path is used to control the robot and the data path is used to control the

tape drive or drives.