Table 25 RAID Manager errors related to manual migration plans (continued)

Required Action

Message

Error Code
(SSB2)

Release the setting of Cache Residency, and then
migrate the volume.

Cache Residency is set on the migration target
volume.

238A

None. LUSE volumes cannot be specified as source
volumes or target volumes.

The migration source volume and the migration
target volume is specified as LUSE volumes.

238B

Cancel the reservation by Business Copy, and then
migrate the volume.

The migration target volume is a reserved volume
of Business Copy.

238C

Perform the user authentication.

The command cannot be executed because the
user authentication is not performed.

9100

Make sure that the specified volume is
implemented.

The pair operation command was rejected
because the specified volume is not implemented.

B911

Make sure that the specified secondary volume is
implemented.

The pair operation command was rejected
because the specified secondary volume is not
implemented.

B912

Specify the mirror ID from 0 to 2.

The pair operation command was rejected
because the mirror ID is invalid.

B913

Troubleshooting when using RAID Manager

51