7.

From within the SMU, select Update > Controller > Flash Firmware.

8.

Under the Flash Firmware banner, click Browse and navigate to the location of the previously-obtained

firmware file, and then click OK.

9.

Wait for a completion message to display.
For example, the following messages are displayed on the MSA controller LCD panel:

MSA1510i updates:

307 FIRMWARE FLASH DONE

MSA20 updates:

313 FIRMWARE FLASH DONE ON BOX <n>
(Each attached storage enclosure is updated one at a time, in sequential box number

order.)

NOTE:

Do not interfere with or cancel the download process. Interrupting the download process

might corrupt the firmware.

10.

Restart the MSA and its attached storage enclosures storage system by doing the following (newly

downloaded firmware cannot be accessed until the MSA is restarted):
a. Press and hold down the MSA Power on/Standby button for approximately five seconds to

place the MSA in Standby mode.

b. Power off all storage enclosures attached to the MSA.
c. Wait approximately two minutes to ensure that the hard disk drives in the enclosures stop

rotating.

d. Restart all storage enclosures attached to the MSA.
e. Wait approximately four minutes to allow the enclosures to complete their startup routines.
f. Press and release the MSA Power on/Standby button to restart the MSA.
g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA

controller LCD panel.

82