Drivetype, Onlinespare, Logical drive category – HP Linux Server Management Software User Manual

Page 44

Advertising
background image

Toolkit utilities 44

If you use Auto method mode, ACU configures all the available drives on the controller into one array. If the

drives are of different capacities, ACU determines the capacity of the smallest drive and uses the same
amount of space on all other available drives.
If you use Custom method mode, choose one of the following methods to specify the drives to be used in the

array. (Different arrays on the same controller can use different methods.)

To specify individual drives, use the applicable convention (port:ID, box:bay, or port:box:bay).

To specify only the number of drives to use (not which specific drive IDs to use), enter that number as the
value for this option. For example, if you enter drive=3, ACU uses the first three available drives to

build or expand the array that you define in the remainder of the script. ACU automatically determines

which drives are suitable to use.

To use all available drives, enter an asterisk as the value for this option. An array that is configured

using this method cannot have a spare.

DriveType

The value that you enter for this option specifies the type of drive (SAS, SATA, or parallel SCSI) that ACU must

use to build the array.

OnlineSpare

The value for this option determines whether the array specified previously in the script will be configured

with spare drives.

Method mode

Possible values

Default value

Custom

To specify exactly which drives to use as spares,

use the applicable convention (port:ID, box:bay,
or port:box:bay).

To specify only the number of spares (not the

exact IDs), enter that number as the value for this
option. ACU automatically selects only those

drives that are suitable for the array.

To specify that the array should not have spares,
enter None.

In Configure action mode: None

In Reconfigure action mode, ACU
ignores any value entered for this

option and keeps any spares that are

already present in the configuration

Auto

Yes (indicating one spare)

No

In Configure action mode: Yes

(indicating one spare)
In Reconfigure action mode, ACU

ignores any value entered for this

option and keeps any spares that are

already present in the configuration

Logical Drive category

The Logical Drive category has the following options:

ArrayAccelerator (on page

45

)

LogicalDrive (on page

45

)

LogicalDriveSSPState (on page

45

)

ParityGroups (on page

45

)

PreferredPath (on page

45

)

Advertising