Installing a dimm – HP ProLiant ML370 G6 Server User Manual

Page 52

Advertising
background image

Hardware options installation 52

Observe the general DIMM slot population guidelines (on page

50

).

DIMM configuration on each channel of a processor must be identical.

Each processor must have a valid Online Spare configuration.

In multi-processor configurations, each processor can have a different valid Online Spare

configuration.

Installing a DIMM

CAUTION:

To avoid damage to the hard drives, memory, and other system components, the air

baffle, drive blanks, and access panel must be installed when the server is powered up.

1.

Power down the server (on page

22

).

2.

Do one of the following:

o

Open or remove the tower bezel, as needed ("

Open or remove the tower bezel

" on page

22

).

o

Extend the server from the rack (on page

24

).

3.

Remove the access panel (on page

25

).

4.

Remove fan 5 (on page

26

).

5.

If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page

27

).

6.

Remove the air baffle (on page

28

).

7.

Open the DIMM slot latches.

8.

Install the DIMM.

9.

Install the air baffle.

10.

If removed, install the BBWC battery pack or the FBWC capacitor pack ("

Installing the BBWC battery

pack or the FBWC capacitor pack

" on page

86

).

11.

Install fan 5.

12.

Install the access panel.

If you are installing DIMMs in lock-step configuration, configure this mode in RBSU ("

HP ROM-Based Setup

Utility

" on page

116

).