Representation in aix, see, Table 6-13 elements of a path – HP XP P9500 Storage User Manual

Page 264

Advertising
background image

#1

The path information is displayed only when a value is specified for the -
path -item parameter.

#2

This storage system applies when the dynamic I/O path control function is

disabled.

Table 6-13 Elements of a Path Name

Element

AIX representation

Corresponding

information

HBA adapter number
(example: 08)

#1

HBA adapter number

The HBA adapter number,

which is displayed by

executing the lsdev -Cc
disk command

Bus number (example:
14)

#1

PCI bus number

The parent bus number,

which is displayed by

executing the lsdev -Cc
disk command

Adapter type (example:
00)

#2

None

Always 00

Adapter number (example:
01)

#2

fscsi number (the xx part

of fscsixx)

The fscsi number, which is

displayed by executing the
lsdev -C command

Target ID (example:

00000000000000E2)

Target ID

The value of scsi_id, which

is displayed by executing

the lsattr -El hdisk-name

command

Host LU number(example:

0001)

Logical unit ID or LUN

The value of lun_id, which

is displayed by executing

the lsattr -El hdisk-name

command

#1

This element is applied when the NPIV option is set to off for the
dlmodmset utility for setting the HDLM execution environment ODM.

#2

This element is applied when the NPIV option is set to on for the
dlmodmset utility for setting the HDLM execution environment ODM.

6-52

Command Reference

Hitachi Dynamic Link Manager User Guide for AIX

®

Advertising
This manual is related to the following products: